Home vibroacoustic therapy device Vitafon-5

299.00$

    Out of stock

    SKU: e654a96bf549 Categories: , Brand:

    Description

    The vibro-acoustic device “VITAFON-5” is intended for application in institutions of therapeutic and prophylactic medicine and sanatoria, as well as at home on the recommendation and under the supervision of a medical specialist.

    The influence of modulated mechanical vibrations of low intensity (microvibration) in the acoustic frequency range on tissues and organs allows to achieve the visible therapeutic effect. When the vibroacoustic transducer directly contacts the surface layers of the skin the microvibration penetrates into the tissues (within the radius and at the depth of 7-10 cm) and a selective effect on different biological structures occurs, and the compensation for deficiency of microvibration in tissues and organs of the human body arises.

    The device has anti-inflammatory, anti-edematous, analgetic, trophic and regenerative effect. It is used for the treatment of functional disorders associated with the disturbance of innervation of organs and tissues, as well as to enhance immunity, promote good health, consolidate the therapeutic effect upon the recovery and as a preventive measure.

    Indications
    Osteochondrosis, radiculitis
    Diseases of the joints, arthritis, rheumatoid polyarthritis
    High blood pressure, including that with a renal origin
    Prostatitis
    Impotence
    Adenoma of the prostate gland
    Inflammation of the epididymis
    Infertility due to blockage of the testicular duct as a result of inflammation (deferentitis)
    Cystitis
    Urinary and faecal incontinence
    Chronic colitis
    Chronic pyelonephritis
    Hemorrhoids
    Constipation
    Maxillary sinusitis
    Head cold, running nose
    Tonsillitis, sore throat
    Bronchitis
    Bronchial asthma
    Insomnia
    Inflammation of the middle ear (otitis)
    Neurosensory hearing disorder
    Fractures
    After-effects (sequel) of spinal injuries
    After-effects (sequel) of infantile cerebral palsy, flaccid paralysis
    Effects (sequel) of scoliosis
    Tissue oedema (swelling), haematoma, bruises, boils, carbuncles, acne
    Wounds, surgical incisions
    Sprains, dislocations
    Burns, scalds
    Frostbite, chilblains
    Corns
    Trophic ulcers
    The mouth -periodontitis, stomatitis, parodontosis
    Chronic gastroduodenitis
    Disruptions of the menstrual cycle
    Serous mastitis, lactostasis
    Cosmetic purposes
    Restoring and developing the voice
    Alleviating fatigue
    In sports training
    Prevention of diseases

    The application of the device is contraindicated:

    – in the near ten centimeters from malignant neoplasms;
    – during pregnancy nearer ten centimeters from the fetus;
    – in the near ten centimeters from a blood clot in case of thrombophlebitis;
    – in the near ten centimeters from the atherosclerotic formation in case of advanced atherosclerosis;

    – in the acute phase of infectious diseases and in case of high (more than 38.5 оС ) temperature of the body (except when there is a specific methodic recommendation);
    – in the vicinity of the implanted pacemakers.

    If in particular body areas there are organs containing stones larger than 4 mm (gall bladder, urinary tract, etc.), the therapy should be preformed only by microvibration of low intensity (vibraphone with white marking) on the recommendation and under the supervision of a doctor or in the availability of emergency care.

    Operational parameters:
    The number of micro vibration frequency subranges :

    • Lower frequency of 1 subrange, within 30±10 Hz
    • Higher frequency of 1 subrange, within 1000±200 Hz
    • Lower frequency of 2 subrange, within 240±80 Hz
    • Higher frequency of 2 subrange, within 8500±1500 Hz

    Duration of one cycle of the micro vibration frequency change:
    60±10 s

    The micro vibration amplitude at lowest frequency:

    • In set with B1 vibrophones 4 ± 2 µm,
    • In set with B2 vibrophones 10 ± 2 µm,
    • In set with quadruple vibrophones B1+B2 (4±2) / (10±2) μm

    Basic technical characteristics:

    • Mains voltage – alternating current 220±22 V
    • Mains frequency 50 Hz
    • Power consumption no more than 8 VA
    • Direct current voltage 12,6 ± 1,3 V
    • Can be used without brake no more than 8h
    • Usually usable for 5 years
    • Weight 2 kg
    • Dimensions:
      – electric block – 121x 70 x 24 mm
      – mains block – 80 x 50 x 90 mm.

    Every device is CE certificated

    Package contains:
    Devices electrical block Vitafon 5 with intagrated battery,

    adaptor for alternating current,

    two sets of vibrophones: dual vibrophones (green) and quadruple vibrophones (dual green and dual white),

    users guide in Russian

    a handbag.

    The parameters for comparison

    Vitafon

    Vitafon – T

    Vitafon – IR

    Vitafon – 2

    Vitafon – 5

    The maximum number of simultaneously connected vibrafone

    2

    2

    1

    10

    6

    Taimer

    yes

    yes

    yes

    IR emitter

    yes

    yes

    The number of operating modes

    4

    4

    4

    7

    9

    Autonomous power supply

    yes

    Weight control unit, kg

    0,35

    0,15

    0,35

    1,5

    0,2

    Weight PSU kg

    0,3

    0,3

    Weight total, kg

    0,6

    0,65

    0,6

    2,6

    1,36 (with Vibroplate 8 – 2,7)

    Additional equipment

    Storage Bag

    Vibroplate 20