Programmable Dosimeter, Geiger Counter Polimaster PM1203M

630.00$

    Out of stock

    Description

    Polimaster’s PM1203M Programmable Dosimeter continuously measures the ambient dose equivalent H*(10) and dose equivalent rate H*(10). Unlike conventional dosimeters with Geiger-Muller detector, this low-cost multipurpose dosimeter is highly sensitive to the low levels of radiation and can register the slightest changes in the natural radiation background.

    Recommended for use by professionals and non-professionals who would like to be alerted with the necessary information to protect themselves from the radiation exposure.

    Polimaster’s PM1203M electronic dosimeter performs following functions:

    • Continuous monitoring of the gamma dose and dose rate;
    • Alert user via audible and visual alarm when the adjustable dose and/or dose rate thresholds are exceeded;
    • Record and store data in its non-volatile memory;
    • Transmit all recorded data via infrared channel to a PC for further processing and analysis;
    • Operates as a regular watch with an alarm clock and calendar functions.

    The instrument’s large and bright LCD screen enables users to view clearly the measurement results.

    PM1203M

    Detector

    GM tube

    Dose Rate display

    0.01 – 2000 μSv/h
    (1 μR/h – 200 mR/h), H*(10)

    Dose Rate Accuracy

    ± (15+1.5/H+0.0025H)%
    (in range 0.1 μSv/h – 2000 μSv/h,
    where H – dose rate in μSv/h)

    Dose measurement

    0.01 – 9999 mSv
    (0.1 mR- 999.9 R)

    Dose Accuracy

    ± 20% (in range 0.01 mSv – 9999 mSv )
    (1 mR – 999.9 R)

    Energy range

    0.06 – 1.5 MeV

    Energy response relative to 0.662 MeV
    (137Cs)

    ± 15 %
    (in range 0.662 – 1.5 MeV)

    Survive after momentary influence of maximum
    permissible gamma radiation within 5 min:

    Standards compliance

    Alarm type:

    visual, audio

    Physical Parameters

    Dimensions

    125 x 42 x 24 mm
    (5” x 1 5/8” x 1”)

    Weight

    90 g (3.17 oz)

    Environmental Characteristics

    Temperature

    -15 up to +60 °C
    (from 5 up to +140 °F)
    from -40 to -15 °C without indication

    Humidity

    up to 80% at 35°C (95°F)

    Environmental protection

    Drop test

    Water resistant

    Power

    Batteries

    2 elements of type V357

    Battery lifetime (average DER not more than 0.3 µSv/h,
    alarms activated for not more than 20 s/24 hours)

    12 months

    *audible signals activated for more than 2 min/24 hours

    Battery discharge control

    LCD indication

    Additional

    Countdown timer

    Display of time to critical exposure

    Functions

    seconds, minutes, hours,
    date, month, year

    Calendar mode

    alarm clock

    PC Communication

    IRDA